Category path
Level 1 categoryGenitourinary System and Sex Hormones
Level 2 categorySex Hormones and Reproductive System Regulators
Level 3 categoryEstrogens
Level 4 categoryNatural and semi-synthetic estrogens, single ingredient
Ingredients
Composition of the kit, reagent preparation and storage conditions] 1. E2 (Estradiol) Standards A-G 7 vials, lyophilized. Before use, add 2.0 ml distilled water to vial A, and 1.0 ml distilled water to vials B-G for dissolution. Use only after complete dissolution. The E2 concentrations after dissolution are: 2. 125I-E2 (125I-Estradiol Derivative) Red solution 50 tubes: 1 vial, radioactivity less than 2.5μCi per vial. 100 tubes: 1 vial, radioactivity less than 5μCi per vial. 3. E2 Antibody 1 vial, solution (blue). 4. Separation Reagent 1 vial, suspension, containing donkey anti-rabbit serum and PEG. Shake well before use, pre-cool at 2-8 ℃. All reagents listed above should be stored at 2-8 ℃. Operating Procedure] After the reagents are fully dissolved, equilibrated to room temperature, and shaken well, proceed as follows (refer to the E2 RIA operating procedure table). 1. Label tubes in pairs: T (total counts), NSB (non-specific binding), A (zero binding), B to G (standard tubes). Label other tubes in pairs for serum samples and quality controls. 2. Add 200μl of zero standard to NSB and A tubes. Add 200μl of corresponding standard to B-G tubes. Add 200μl of corresponding patient serum and quality control to other tubes. Add 100μl of E2 antibody to all tubes (except NSB and T tubes), and shake well. Incubate at 20±1 ℃ for 2 hours. 3. Add 100μl of 125I-E2 derivative to all tubes, and shake well. Incubate at 20±1 ℃ for 1 hour. 4. Add 0.5 ml of cold separation reagent to all tubes (except T tube), and shake well. Let stand at room temperature for 10 minutes. 5. Centrifuge at 3500 rpm for 20 minutes. 6. Discard the supernatant (except for T tube). Count the radioactivity of the precipitate in each tube and T tube for 60 seconds. ![ Calculation of Results] ![ Plot a standard curve on semi-logarithmic paper with standard concentrations on the x-axis and B/B0% on the y-axis. The E2 content in serum samples can be determined from the standard curve based on their B/B0% values. Alternatively, the E2 content in serum samples can be automatically calculated by the instrument program. It is recommended to use the four-parameter method for processing. [Example of Standard Curve] !" />. 3. Accuracy The recovery rate was 101.5 – 114% when low, medium, and high known concentrations of E2 were added to serum samples. 4. Non-specific binding rate (NSB/T%) 0/T%) ≥ 30%.