Basic information
Drug category type
250mL
Specification
250mL
Standard dose
—
Approval number
Sign in and subscribe to view this field
Execution standard
Imported Drug Registration Standard: JX20160037
Shelf life
Sign in and subscribe to view this field
Product information
This product is a colorless and clear liquid, highly volatile. Sevoflurane for inhalation (hereinafter referred to as sevoflurane) is a halogenated inhaled general anesthetic, non-flammable, non-explosive, volatile liquid, used after vaporization. Some physical constants of sevoflurane are: Molecular Weight 200.05 Boiling Point at 760 mmHg 58.6 ℃ Specific Gravity at 20 ℃ 1.520-1.525 Vapor Pressure mmHg 20 ℃ 157 25 ℃ 197 36 ℃ 317 Partition Coefficients at 37 ℃: Blood/Gas 0.63-0.69 Water/Gas 0.36 Olive Oil/Gas 47-54 Brain/Gas 1.15 Average component/gas partition coefficients of sevoflurane for medical polymers at 25 ℃: Conductive Rubber 14.0 Butyl Rubber 7.7 Polyvinyl Chloride 17.4 Polyethylene 1.3 The characteristics of sevoflurane, as described in IEC 601-2-13 requirements, are non-flammable and non-explosive. Sevoflurane is a colorless, clear liquid without additives, non-corrosive to stainless steel, brass, aluminum, nickel-plated brass, chrome-plated brass, and beryllium copper. It is non-irritating, miscible with ethanol, ether, chloroform, and benzene, and slightly soluble in water. Samples stored under normal room light conditions as required remain stable. Sevoflurane shows no significant visible degradation under strong acid or alkaline conditions or heating. When exposed to alkaline carbon dioxide (CO2) absorbents (such as Baralyme® and small amounts of soda lime) in an anesthesia machine, sevoflurane can degrade under certain conditions. The extent of sevoflurane degradation is minor, and degradation products are either undetectable or produced in non-toxic amounts when fresh absorbent is used directly. The degradation of sevoflurane and the formation of its degradation products are enhanced with increasing absorbent temperature and sevoflurane concentration, decreasing fresh gas flow, and pulverization of the CO2 absorbent (especially in absorbents containing potassium hydroxide, such as Baralyme). Sevoflurane undergoes alkaline degradation via two pathways. The first is due to the loss of hydrogen fluoride and the formation of pentafluoroisopropenyl fluoromethyl ether (abbreviated as PIFE, molecular formula C4H2F6O, also known as Compound A) and trace amounts of pentafluoromethoxyisopropyl-fluoromethyl ether (abbreviated as PMFE, molecular formula C5H6F6O). The second degradation pathway primarily occurs in the presence of desiccated CO2 absorbents. See below for details. In the first degradation pathway, i.e., the defluorination pathway, the degradation product in the anesthesia circuit is the olefinic Compound A, formed by the loss of an acidic proton from sevoflurane under strong alkaline conditions (KOH or NaOH), similar to the degradation of halothane to 2-bromo-2-chloro-1,1-difluoroethylene (BCDFE). Laboratory simulation tests have shown that the concentration of these degradation products is inversely proportional to the fresh gas flow rate. (See Figure 1) Figure 1: Compound A levels versus fresh gas flow rate in a circle absorption system Fresh Gas Flow—L/min Since CO2 absorption is an exothermic reaction, the temperature increase depends on the amount of CO2 absorbed, which in turn depends on the fresh gas flow rate in the anesthesia circuit system, the patient's metabolic state, and ventilation. An in vitro simulation experiment adding CO2 to a circle absorption system can explain the relationship between different CO2 concentrations, different Compound A yields, and temperature. Figure 2: Relationship between Compound A levels, CO2 flow rate, and maximum temperature CO2 Flow Rate (mL/min) In the circle absorption system, the increase in Compound A concentration is a combined effect of increased CO2 absorbent temperature and its composition (Baralyme produces more Compound A compared to soda lime), increased body temperature, increased minute ventilation, and decreased fresh gas flow rate. It has been reported that Baralyme in a prolonged dry state can significantly increase Compound A concentrations. It has also been shown that patient exposure to Compound A increases with increasing sevoflurane concentration and prolonged anesthesia time. In one clinical study, sevoflurane was administered at a low flow rate for more than 2 hours, at a flow rate of 1 liter/minute, and Compound A concentrations were measured to determine the relationship between MAC (minimum alveolar concentration) hours and the Compound A levels produced. The relationship between Compound A levels and sevoflurane exposure is shown in Figure 2a. Figure 2a: ppm•hr vs. MAC•hr at a flow rate of 1 L/min The second degradation pathway of sevoflurane primarily involves dissociation into hexafluoroisopropanol (HFIP) and formaldehyde under carbon dioxide absorbents. Hexafluoroisopropanol is inactive, non-genotoxic, and rapidly glucuronidated and cleared by the liver. Formaldehyde exists in normal metabolic processes and, upon exposure to highly desiccated absorbents, further degrades into methanol and formate. Formate can promote carbon monoxide production at high temperatures, and the formation of high temperatures is associated with Baralyme®. Methanol reacts with Compound A to form pentafluoromethoxy-isopropyl-fluoromethyl ether. This compound further eliminates hydrogen fluoride (HF) to form other compounds. Sevoflurane degradation products have been observed in the breathing circuits of experimental anesthesia machines using desiccated CO2 absorbents and the highest concentration of sevoflurane (8%) for prolonged periods (≥ 2 hours). Formaldehyde concentrations observed in the breathing circuits of these experimental anesthesia machines using desiccated soda lime were consistent with levels that could cause respiratory irritation. Although CO2 absorbents containing potassium hydroxide (KOH) are no longer commercially available, in this laboratory experiment, sevoflurane exposure to desiccated CO2 absorbents containing potassium hydroxide (KOH) (Baralyme) resulted in significantly elevated levels of degradation products.
Store at room temperature 15-30 ℃ (59-86℉). The cap should be tightly closed after each use.
Sign in and subscribe to view this field
Sign in and subscribe to view this field
Imported Drug Registration Standard: JX20160037
Sign in and subscribe to view this field
Sign in and subscribe to view this field
Sign in and subscribe to view this field
SinoMDB organizes public medical resource data for information reference only. This content is not medical advice, diagnosis, or treatment guidance. Please consult qualified medical professionals before making healthcare decisions.
Medicine Data Sources
See how SinoMDB organizes medicine information from public regulatory records, clinical medication references, and drug interaction materials.